Difference between revisions of "DATA COLLECTION"

From SPGC Document Wiki
Jump to: navigation, search
 
(62 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
[[Main_Page | Main Page]] > [[Application_Development_Team | Application Development Team]] > [[System_Manual | System Manual]] > [[DATA_COLLECTOR |DATA COLLECTOR]]
 +
[[File:555e.jpg|300px|center]]
  
 
'''I. Collect Data'''
 
'''I. Collect Data'''
  
'''Key Layout''':
+
'''''Key Layout''''':
  
Alphanumeric keypad is set to numeric mode by default. The [FN/ALPHA]
+
        Alphanumeric keypad is set to numeric mode by default. The [FN/ALPHA]
as a toggle among in numeric, alpha (lower-case alphabetic), ALPHA (upper-case
+
  as a toggle among in numeric, alpha (lower-case alphabetic), ALPHA (upper-case
alphabetic) input modes.
+
  alphabetic) input modes.
  
''Note: It is not necessary to hold down the FN/Alpha key''.
+
      ''Note: It is not necessary to hold down the FN/Alpha key''.
  
The associated icon will appear on the lower-right corner of the screen in a sequence as
+
        The associated icon will appear on the lower-right corner of the screen in a         sequence as shown below.
shown below.
+
        '''Screen Icon              FN/ALPHA KEY                      Input Mode'''
 +
          (none)                      N/A                          Numbers
 +
              A            Press[FN/ALPHA] one time            Upper-case alphabetic
 +
              a            Press[FN/ALPHA] two times            Lower-case alphabetic
 +
              F            Press[FN/ALPHA] three times          Function mode
 +
  
'''Screen Icon FN/ALPHA KEY Input Mode'''
 
(none) N/A Numbers
 
  
A Press [FN/ALPHA] one time Upper-case alphabetic
+
 +
'''Process''':
 +
  1. After clicking the '''Power On''' button the device selection menu will
 +
    display.
  
a Press [FN/ALPHA] two times Lower-case alphabetic
+
  2. Click '''Enter/OK''' button.
  
F Press [FN/ALPHA] three times Function mode
+
  3. Input the Store Name then click '''Enter/OK''' button.
  
'''Process''':
+
  4. Next input the Sell/Stock area
  
1. After clicking the '''Power On''' button the device selection menu will
+
  5. After inputting the Sell/Stock area click '''Enter/OK''' button.
display.
+
  
2. Click '''Enter/OK''' button.
+
  6. Then input the name of the Checker press '''Enter/OK''' button again.
  
3. Input the Store Name then click '''Enter/OK''' button.
+
  7. Press the '''Scan''' button to get the barcode of the item.
  
4. Next input the Sell/Stock area
+
  8. Next input the number of quantity.
  
5. After inputting the Sell/Stock area click '''Enter/OK''' button.
+
  9. Then click '''Enter/OK''' button.
  
6. Then input the name of the Checker press '''Enter/OK''' button again.
+
  10. To scan another items repeat the steps from STEP 6 – STEP 8.
  
7. Press the '''Scan''' button to get the barcode of the item.
+
      ''Note: If you want to change the Store Name, Sell/Stock area and Checker click
 +
  the Back/Cancel button once for you to return in STEP 3''.
  
8. Next input the number of quantity.
+
'''II. Upload Data'''
  
9. Then click '''Enter/OK''' button.
+
    ''Note: Before you start the steps in uploading data, be sure that your device was          properly''connected to your Computer same as the figure shown below''''.
 +
[[File:111a.jpg|500px|center]]
  
10. To scan another items repeat the steps from STEP 6 – STEP 8.
+
  '''''Process''''':
  
Note: If you want to change the Store Name, Sell/Stock area and Checker click
+
  1. Open '''Remote Console''' application installed in your computer.
the Back/Cancel button once for you to return in STEP 3.
+
[[File:222b.jpg|center|600px]]
FN/ALPHA
+
  
SCAN
+
    ''Note: If '''Remote Console''' window did not display after clicking the
 +
  application. See the '''Toolbars''' then look for the icon of '''Remote Console'''
 +
 
 +
  Point the mouse in the icon.
 +
  Next right click.
 +
  Then select/choose '''Maximise'''''.
  
'''II. Upload Data'''
+
  2. Click '''System''' menu placed on the upper part of the '''Remote Console'''
 +
    window.
  
''Note: Before you start the steps in uploading data, be sure that your device was properly
+
  3. Next Click the '''Link Properties'''.
connected to your Computer same as the figure shown below.''
+
  
'''Process''':
+
  4. In the '''Link Property Window''', click the dropdown button inline with
 +
    label/word '''Interface'''.
  
1. Open '''Remote Console''' application installed in your computer.
+
  5. Next choose/select '''Cradle IR'''.
  
''Note: If '''Remote Console''' window did not display after clicking the
+
  6. Then beside '''Port''' input 9, to assign which data collector the user wants to
application. See the '''Toolbars''' then look for the icon of '''Remote Console'''
+
    access/connect.
Point the mouse in the icon.
+
  System Menu
Next right click.
+
Then select/choose '''Maximise'''''.
+
  
2. Click '''System''' menu placed on the upper part of the '''Remote Console'''
+
  7. After assign the data collector, go back on the device (data collector)
window.
+
  choose the '''Upload''' menu, by just simply clicking the drop down button
 +
  then press '''Enter/OK''' button (after turning on the device). Wait until the
 +
  device is totally connected.
  
3. Next Click the '''Link Properties'''.
+
  8. Next go back to the System ('''Remote Console''') click the '''Play/Start''' button
 +
  placed on the left side upper part of the window. Wait until the Data
 +
  Collector device will display a message that states “Sending Transf.:
 +
  done”.
  
4. In the '''Link Property Window''', click the dropdown button inline with
+
  9. Then data collector will ask which data user wants to delete, just choose
label/word '''Interface'''.
+
    one and then press '''Enter/OK''' button.
  
5. Next choose/select '''Cradle IR'''.
+
  10. A confirmation message will display then just choose if Yes/No and click
 +
    '''Enter/OK''' button.
  
6. Then beside '''Port''' input 9, to assign which data collector the user wants to
+
  11. Then click the Stop button placed beside the '''Play/Start''' button in
access/connect.
+
    '''Remote Console''' window.
System Menu
+
  
7. After assign the data collector, go back on the device (data collector)
+
  12. To view the uploaded file, go back to the '''Remote Console''' window.
choose the '''Upload''' menu, by just simply clicking the drop down button
+
 
then press '''Enter/OK''' button (after turning on the device). Wait until the
+
  13. On the left side of the window click '''Files''' and the uploaded files will
device is totally connected.
+
display.
  
8. Next go back to the System ('''Remote Console''') click the '''Play/Start''' button
+
'''III. File Format'''
placed on the left side upper part of the window. Wait until the Data
+
[[File:333c.jpg|600px|center]]
Collector device will display a message that states “Sending Transf.:
+
done”.
+
  
9. Then data collector will ask which data user wants to delete, just choose
+
  1. In the '''Remote Console''' window click '''System''' menu.
one and then press '''Enter/OK''' button.
+
  
10. A confirmation message will display then just choose if Yes/No and click
+
  2. Next select '''File Properties'''.
'''Enter/OK''' button.
+
 
+
11. Then click the Stop button placed beside the '''Play/Start''' button in
+
'''Remote Console''' window.
+
 
+
12. To view the uploaded file, go back to the '''Remote Console''' window.
+
 
+
13. On the left side of the window click '''Files''' and the uploaded files will
+
display.
+
  
'''III. File Format'''
+
  3. File naming rules will display.
 +
    System Menu
 +
[[File:444.jpg|600px|center]]
  
1. In the '''Remote Console''' window click '''System''' menu.
+
  4. In rule number 6, beside '''File Name Format''' label input the
 +
    number of rule you want to include in saving/uploading the
 +
    file/data in the textbox provided.
  
2. Next select '''File Properties'''.
+
  5. The series of the inputted rule numbers are the basis which rule
 +
  number will comes first in uploading/saving the file.
  
3. File naming rules will display.
+
  6. User can set the path where the file should be uploaded by
System Menu
+
  simply clicking browse in the '''File Path''' layer.
  
4. In rule number 6, beside '''File Name Format''' label input the
+
  7. Next select the location and click '''OK'''.
number of rule you want to include in saving/uploading the
+
file/data in the textbox provided.
+
  
5. The series of the inputted rule numbers are the basis which rule
+
  8. User can also set the extension name of the file by simply
number will comes first in uploading/saving the file.
+
    inputting the extension name in the textbox placed beside the
 +
    label '''Data Filename Extension'''.
  
6. User can set the path where the file should be uploaded by
+
  9. Then click '''OK''' button.
simply clicking browse in the '''File Path''' layer.
+
  
7. Next select the location and click '''OK'''.
+
 +
== '''Reference''' ==
 +
  [[Media:DATA_COLLECTOR_USER'S_MANUAL.pdf|DATA COLLECTOR USER’S MANUAL Document]]
  
8. User can also set the extension name of the file by simply
 
inputting the extension name in the textbox placed beside the
 
label '''Data Filename Extension'''.
 
  
9. Then click '''OK''' button.
+
[[Main_Page | Main Page]] > [[Application_Development_Team | Application Development Team]] > [[System_Manual | System Manual]] > [[DATA_COLLECTOR |DATA COLLECTOR]]

Latest revision as of 09:29, 1 September 2016

Main Page > Application Development Team > System Manual > DATA COLLECTOR

555e.jpg

I. Collect Data

Key Layout:

       Alphanumeric keypad is set to numeric mode by default. The [FN/ALPHA]
 as a toggle among in numeric, alpha (lower-case alphabetic), ALPHA (upper-case
 alphabetic) input modes.
     Note: It is not necessary to hold down the FN/Alpha key.
       The associated icon will appear on the lower-right corner of the screen in a          sequence as shown below.
        Screen Icon              FN/ALPHA KEY                      Input Mode
          (none)                       N/A                          Numbers
             A             Press[FN/ALPHA] one time             Upper-case alphabetic
             a             Press[FN/ALPHA] two times            Lower-case alphabetic
             F             Press[FN/ALPHA] three times          Function mode


Process:
 1. After clicking the Power On button the device selection menu will
    display.
 2. Click Enter/OK button.
 3. Input the Store Name then click Enter/OK button.
 4. Next input the Sell/Stock area
 5. After inputting the Sell/Stock area click Enter/OK button.
 6. Then input the name of the Checker press Enter/OK button again.
 7. Press the Scan button to get the barcode of the item.
 8. Next input the number of quantity.
 9. Then click Enter/OK button.
 10. To scan another items repeat the steps from STEP 6 – STEP 8.
     Note: If you want to change the Store Name, Sell/Stock area and Checker click
 the Back/Cancel button once for you to return in STEP 3.

II. Upload Data

    Note: Before you start the steps in uploading data, be sure that your device was          properlyconnected to your Computer same as the figure shown below'.
111a.jpg
  Process:
 1. Open Remote Console application installed in your computer.
222b.jpg
    Note: If Remote Console window did not display after clicking the
 application. See the Toolbars then look for the icon of Remote Console
 
 Point the mouse in the icon.
 Next right click.
 Then select/choose Maximise.
 2. Click System menu placed on the upper part of the Remote Console
   window.
 3. Next Click the Link Properties.
 4. In the Link Property Window, click the dropdown button inline with
   label/word Interface.
 5. Next choose/select Cradle IR.
 6. Then beside Port input 9, to assign which data collector the user wants to
    access/connect.
  System Menu
 7. After assign the data collector, go back on the device (data collector)
  choose the Upload menu, by just simply clicking the drop down button
  then press Enter/OK button (after turning on the device). Wait until the
  device is totally connected.
 8. Next go back to the System (Remote Console) click the Play/Start button
  placed on the left side upper part of the window. Wait until the Data
  Collector device will display a message that states “Sending Transf.:
  done”.
 9. Then data collector will ask which data user wants to delete, just choose
   one and then press Enter/OK button.
 10. A confirmation message will display then just choose if Yes/No and click
   Enter/OK button.
 11. Then click the Stop button placed beside the Play/Start button in
   Remote Console window.
 12. To view the uploaded file, go back to the Remote Console window.
 
 13. On the left side of the window click Files and the uploaded files will

display.

III. File Format
333c.jpg
 1. In the Remote Console window click System menu.
 2. Next select File Properties.
 3. File naming rules will display.
   System Menu
444.jpg
 4. In rule number 6, beside File Name Format label input the
   number of rule you want to include in saving/uploading the
   file/data in the textbox provided.
 5. The series of the inputted rule numbers are the basis which rule
  number will comes first in uploading/saving the file.
 6. User can set the path where the file should be uploaded by
  simply clicking browse in the File Path layer.
 7. Next select the location and click OK.
 8. User can also set the extension name of the file by simply
   inputting the extension name in the textbox placed beside the
   label Data Filename Extension.
 9. Then click OK button.


== Reference ==
  DATA COLLECTOR USER’S MANUAL Document


Main Page > Application Development Team > System Manual > DATA COLLECTOR